Snap it, don't type it

Snap the data plate. Skip the typos.

Take one photo of the condenser, furnace or air handler label. You get the brand, model, serial number and manufacture date on the job, with no squinting and no typos on the parts order.

No retyping Model and serial from one photo
Dim light. Older units. Read nameplate details in tough conditions
Know how old it is Manufacture date on the record

Never Squint or Retype Model Numbers Again

Built for dark attics, blinding rooftop glare, and greasy mechanical rooms.

⚡

No wrong part on the order

Mistyping a '0' for an 'O' or a '1' for an 'I' ruins the parts order. Read it off the photo, check it against the label, and fix anything before you save.

📋

Scan the unit once

Every saved nameplate stays on file. On the next visit, choose Use previous to attach it again instead of rescanning.

📄

Right unit on the paperwork

Attach the nameplate to the diagnosis so the job record names the exact model and serial you worked on.

How many tons is this unit?

Type a condenser or furnace model number, or click a sample, to read the size out of it:

Or select a real brand model:
MODEL: 4TTR4036L1000AA
SERIAL: 21345N442F
AI Optical Recognition Active
Trane / American Standard

4TTR4036L1000AA

✓ Decoded
Nominal Cooling Capacity 3.0 Tons (36,000 BTU/hr) Derived from capacity digits "036" (36 / 12 = 3.0)
Efficiency Rating 14 SEER High-Efficiency Single-Stage Condenser
Estimated Manufacture Date Week 34, 2021 (~5 Years Old) Extracted from Serial # prefix logic
Electrical Specifications 208/230V, 1 Phase, 60Hz Standard residential split system supply

HVAC Model Number Capacity Decoder Key

How nominal BTU numbers inside model strings translate into tons of cooling:

018 1.5 Tons 18,000 BTU/hr

Typical airflow: 600 CFM

024 2.0 Tons 24,000 BTU/hr

Typical airflow: 800 CFM

030 2.5 Tons 30,000 BTU/hr

Typical airflow: 1,000 CFM

036 3.0 Tons 36,000 BTU/hr

Typical airflow: 1,200 CFM

042 3.5 Tons 42,000 BTU/hr

Typical airflow: 1,400 CFM

048 4.0 Tons 48,000 BTU/hr

Typical airflow: 1,600 CFM

060 5.0 Tons 60,000 BTU/hr

Typical airflow: 2,000 CFM

Nameplate scanner FAQ

Does the camera scanner require cell reception or internet?

Not for Scan Free. It reads the label on your phone, saves with no signal and syncs later. Scan Pro fills in the fields for you but needs internet. Compare Scan Free and Scan Pro.

How does ACLogics determine the equipment manufacturing date?

Each major manufacturer embeds manufacturing dates into serial numbers differently (e.g. Carrier uses first two digits for week and next two for year; Trane uses the first two digits for year and week; Goodman uses year and month prefix). When the date is read from the serial instead of printed on the label, ACLogics marks it ESTIMATED so you know to double-check it.

What if the scan gets something wrong?

Check every field against the label before you save, especially model and serial. Tap a field to correct it. If the photo can't be read, retake it with less glare or type the details in.

Snap, don't type

Get the unit on the job in one photo.

Download ACLogics free for iOS and Android. Try for free — no credit card needed. Snap the data plate, check it, and attach it to the call.