What It Means

Fault on the fan coil's electrostatic dust-collecting air cleaner, an optional accessory fitted in the return-air path upstream of the coil rather than a refrigerant- or water-side component.

Possible Causes

  • Dust-collecting element fouled, saturated, or damaged and no longer holding charge correctly.
  • Insulator section of the element tracking or contaminated with grease/dust, causing leakage current.
  • Failed high-voltage power supply unit for the electrostatic cleaner.
  • Defective indoor (fan coil) unit PCB controlling the dust-collector circuit.
  • Loose or damaged wiring/connector between the PCB and the high-voltage unit.

Not sure which one it is — or if it's none of these? Try ACLogics today.

Disclaimer: This information is for general reference. Error codes can vary by model and production year. Always refer to your machine's specific manual and the information printed on the unit itself.
New to this code? Click to see why this happens

Full Diagnosis

Fault on the fan coil's electrostatic dust-collecting air cleaner, an optional accessory fitted in the return-air path upstream of the coil rather than a refrigerant- or water-side component. The unit applies high voltage across the collecting element to charge and trap airborne particulate; when the element, its insulator, or the high-voltage supply faults, the controller de-energizes the electrostatic cleaner and flags the fault while normal fan and coil operation can continue. Unlike C4, which flags a failed heat-exchanger liquid-pipe thermistor on the coil itself, AH is isolated to the accessory air-cleaning module and does not indicate a coil or water-side problem.

All Recorded Causes

Dust-collecting element fouled, saturated, or damaged and no longer holding charge correctly Insulator section of the element tracking or contaminated with grease/dust, causing leakage current Failed high-voltage power supply unit for the electrostatic cleaner Defective indoor (fan coil) unit PCB controlling the dust-collector circuit Loose or damaged wiring/connector between the PCB and the high-voltage unit

Verify Before Replacing Parts

  1. Confirm the exact Daikin model family and fan coil context before acting on a generic code description.
  2. Verify airflow first, then confirm operating pressures and temperature relationship before adjusting charge, since dust-collecting element fouled, saturated, or damaged and no longer holding charge correct….
  3. Look for restrictions, iced coils, or dirty heat-transfer surfaces that can mimic a charge problem, and separately confirm insulator section of the element tracking or contaminated with grease/dust, causing leakag….
  4. After the correction, run the system long enough to confirm the fan coil fault does not return under normal load.