What It Means
Auxiliary safety circuit (secondary limit or flame rollout) switch is open.
Troubleshooting guide for the Lennox system fault Slow Flash / On.
Auxiliary safety circuit (secondary limit or flame rollout) switch is open.
Not sure which one it is — or if it's none of these? Try ACLogics today.
Limit or Rollout Switch Open (Auxiliary Circuit). This alternate flash order — DS2 solid on while DS1 slow-flashes — flags the auxiliary safety circuit (typically the flame rollout or secondary limit switch) as open, distinct from the primary high-limit trip signaled by On / Slow Flash. When it trips, the board immediately shuts off the gas valve and igniter, the inducer keeps running to clear the heat exchanger, and the blower may continue running or ramp up to dump residual heat depending on the model. Once the switch cools and resets, the furnace will attempt to restart the heat cycle automatically.
Dirty or clogged filter restricting return air, blocked or closed supply/return registers, undersized or crushed flex duct, wrong blower speed tap selected for the BTU input, blower wheel loose on its shaft or coated in dust, restricted flue/vent causing poor draft (common with rollout trips), or a failed/miswired limit or rollout switch — check static pressure and ohm the switch cold before replacing parts.