What It Means
Temporary anti-short-cycle power-up delay active.
Troubleshooting guide for the Trane AC & Heat Pump system fault Green LED (Fast Flash – 5x/second).
Temporary anti-short-cycle power-up delay active.
Not sure which one it is — or if it's none of these? Try ACLogics today.
Power-up (anti-short-cycle) delay — after a power interruption or a new call for cooling/heat, the control board holds the compressor off for a short fixed delay to protect it from short-cycling, signaled by a fast green flash. This is a temporary, self-clearing state, unlike Green LED Slow Flash (settled standby with no call) or Green LED Intermittent Flash (a hard lockout that will NOT clear on its own). Once the delay timer expires, the LED should drop to the medium-flash active-run rate and the compressor will start.
No action needed — allow the unit a few minutes to complete its startup delay. If the LED stays on fast-flash well beyond a normal power-up delay and the compressor never starts, the timer may be stuck or a separate fault may be masked; power-cycle the system once, and if fast-flash with no compressor start persists, call a technician rather than continuing to reset it.