What It Means
Limit or flame rollout switch open longer than 3 minutes or 10 limit trips in high heat.
Troubleshooting guide for the Carrier Furnace system fault 13.
Limit or flame rollout switch open longer than 3 minutes or 10 limit trips in high heat.
Not sure which one it is — or if it's none of these? Try ACLogics today.
Limit Circuit Lockout. Lockout occurs if the limit or flame rollout switch is open longer than 3 minutes or after 10 successive limit trips during high heat; auto reset after 3 hours.
Check for restricted airflow (dirty filter, blocked registers). Inspect limit switch and flame rollout switch for continuity. Verify blower motor operation. Check heat exchanger for cracks or obstructions.
ACLogics walks you through Carrier Furnace diagnostics step-by-step — so you confirm the cause before swapping parts.