Carrier Furnace

Carrier Furnace Error Code 42

Troubleshooting guide for the Carrier Furnace system fault 42.

What It Means

Inducer motor failed to start, run at correct RPM, or lost speed signal.

Possible Causes

  • Loose or damaged inducer motor wiring connection.
  • Debris blocking inducer wheel.
  • Faulty inducer capacitor or motor assembly.
  • Damaged RPM feedback signal wire.

Not sure which one it is — or if it's none of these? Try ACLogics today.

Disclaimer: This information is for general reference. Error codes can vary by model and production year. Always refer to your machine's specific manual and the information printed on the unit itself.
New to this code? Click to see why this happens

Full Diagnosis

Inducer Motor Fault. Inducer has not started within 20 seconds after a call for heat, RPM is out of range, or RPM signal was lost for 5 seconds during operation.

All Recorded Causes

Check inducer motor wiring and connectors. Inspect for debris or blockage in inducer wheel. Test motor capacitor. Verify RPM feedback signal wire integrity. Replace inducer motor if defective.

Verify Before Replacing Parts

  1. Confirm the exact Carrier model family and furnaces context before acting on a generic code description.
  2. Walk the entire heating sequence in order instead of jumping straight to the reported code, watching for check inducer motor wiring and connectors.
  3. Verify each safety device and prove where the sequence stops under live operation, including whether inspect for debris or blockage in inducer wheel.
  4. After the correction, run the system long enough to confirm the furnaces fault does not return under normal load.