Rheem AC & Heat Pump

Rheem AC & Heat Pump Error Code 29

Troubleshooting guide for the Rheem AC & Heat Pump system fault 29.

What It Means

High pressure switch open on outdoor unit.

Possible Causes

  • Dirty outdoor condenser coil.
  • Inoperative outdoor fan motor.
  • Refrigerant overcharge.
  • Liquid line restriction.
  • Faulty high pressure switch.

Not sure which one it is — or if it's none of these? Try ACLogics today.

Disclaimer: This information is for general reference. Error codes can vary by model and production year. Always refer to your machine's specific manual and the information printed on the unit itself.
New to this code? Click to see why this happens

Full Diagnosis

High pressure control open.

All Recorded Causes

Dirty outdoor coil, outdoor fan not running, refrigerant overcharge, liquid-line restriction, dirty indoor coil/filter in heating mode, indoor blower issue, or faulty high-pressure control.

Verify Before Replacing Parts

  1. Confirm the exact Rheem model family and ac and heat pump context before acting on a generic code description.
  2. Verify airflow first, then confirm operating pressures and temperature relationship before adjusting charge, since dirty outdoor coil, outdoor fan not running, refrigerant overcharge, liquid-line restricti….
  3. Look for restrictions, iced coils, or dirty heat-transfer surfaces that can mimic a charge problem, and separately confirm the next candidate on the list.
  4. After the correction, run the system long enough to confirm the ac and heat pump fault does not return under normal load.

Not sure which system this Rheem code is on?

ACLogics has guided diagnostics for 57 Rheem fault codes and asks the right questions to narrow it down.

See how ACLogics diagnoses Rheem units →