Rheem AC & Heat Pump

Rheem AC & Heat Pump Error Code P

Troubleshooting guide for the Rheem AC & Heat Pump system fault P.

What It Means

Compressor internal thermal protector tripped.

Possible Causes

  • Compressor wiring or contactor fault.
  • Failed capacitor or start components.
  • Internal thermal overload trip.
  • Low line voltage or seized compressor.

Not sure which one it is — or if it's none of these? Try ACLogics today.

Disclaimer: This information is for general reference. Error codes can vary by model and production year. Always refer to your machine's specific manual and the information printed on the unit itself.
New to this code? Click to see why this happens

Full Diagnosis

Compressor protector trip.

All Recorded Causes

Command for compressor operation is present but no compressor current is measured. Check compressor wiring, contactor, capacitor/start components, thermal overload, line voltage, and compressor condition.

Verify Before Replacing Parts

  1. Confirm the exact Rheem model family and ac and heat pump context before acting on a generic code description.
  2. Verify current draw, overload status, and control signal before condemning the compressor or drive, given that command for compressor operation is present but no compressor current is measured.
  3. Look for upstream conditions such as airflow or charge issues that may be pushing the compressor into protection, and check check compressor wiring, contactor, capacitor/start components, thermal overload, line vol….
  4. After the correction, run the system long enough to confirm the ac and heat pump fault does not return under normal load.