What It Means
Compressor discharge line thermal over-temperature protection trip.
Troubleshooting guide for the Luxaire system fault P4.
Compressor discharge line thermal over-temperature protection trip.
Not sure which one it is — or if it's none of these? Try ACLogics today.
A thermal protection trip triggered when the compressor discharge line temperature actually exceeds the safe operating limit — distinct from F25, which reports a failure of the discharge sensor itself rather than a real overtemperature event. P4 typically locks out the compressor for a cooldown period and, like the other discharge/pressure protections such as P2 and P6, may need to trip several times before the board latches a persistent fault.
Check refrigerant charge — both overcharge and undercharge can drive discharge temperature out of range. Inspect the outdoor condenser coil and fan for airflow restriction, dirt buildup, or a failing fan motor that reduces heat rejection. Verify indoor airflow is adequate if the unit is in heating mode. Confirm the discharge sensor itself is reading accurately, and inspect for a worn or failing compressor if charge and airflow check out.