What It Means
Liquid line temperature thermistor open or shorted.
Troubleshooting guide for the American Standard AC & Heat Pump system fault Red 11 Flashes.
Liquid line temperature thermistor open or shorted.
Not sure which one it is — or if it's none of these? Try ACLogics today.
Liquid line temperature sensor fault (open or shorted) — the thermistor on the liquid line has failed, so the board loses its reading of refrigerant temperature at that point in the circuit. This sensor feeds subcooling and demand-defrost calculations, and is distinct from Red 12 (the liquid-line pressure transducer, a separate component monitoring pressure rather than temperature) and Red 6 (the coil sensor, located at the outdoor coil rather than the liquid line). Loss of this input can affect defrost timing and staging accuracy until it's repaired.
Locate the liquid-line temperature sensor (typically clamped to or inserted near the liquid line at the outdoor unit) and check that its connector is fully seated and undamaged. Look for corrosion, chafed wire insulation, or a connector that has backed out of its housing, reseat it, and cycle power to see if the fault clears. If the sensor's reading stays open or shorted with wiring confirmed good, replace the sensor itself rather than the control board.