What It Means
Inverter communication break (V9+) or suction thermistor out of range (V8/earlier).
Troubleshooting guide for the Bryant Heat Pump system fault 58.
Inverter communication break (V9+) or suction thermistor out of range (V8/earlier).
Not sure which one it is — or if it's none of these? Try ACLogics today.
Lost Inverter Communication Event (V9+) / Suction Thermistor Range Fault (V8 and earlier). Communication or thermistor fault detected. This is one of Bryant's version-dependent codes, so the same numeral means two different faults depending on control board software: on V9+ boards it flags a break in the serial link between the control board and inverter module, halting inverter-driven compressor operation until communication is restored; on V8 and earlier boards it instead flags a suction thermistor reading outside its valid range, disabling temperature-dependent protections such as suction over-temp monitoring that rely on that sensor. Either way the outdoor unit stops running the affected function while the indoor blower and any backup heat keep operating. It differs from code 48 (Lost Inverter Communications), which is the non-version-specific communications-loss code present across all software versions, whereas 58's communications meaning applies only to V9+ boards — confirm software version before diagnosing, since chasing inverter wiring on a V8 board when the real issue is a suction thermistor wastes a service call.
First confirm control board software version (V9+ vs. V8 or earlier) since the fault meaning depends on it. V9+: check inverter communication wiring and connectors for damage or looseness, and power cycle the unit to attempt to re-establish the link before replacing the inverter board. V8 and earlier: check suction thermistor wiring for damage and measure resistance against the temperature/resistance chart at the current suction line temperature. Replace whichever component — inverter board or suction thermistor — is confirmed faulty for the board's software version; replacing the wrong one will not clear the code.
ACLogics walks you through Bryant Heat Pump diagnostics step-by-step — so you confirm the cause before swapping parts.