Bryant Heat Pump

Bryant Heat Pump Error Code 71

Troubleshooting guide for the Bryant Heat Pump system fault 71.

What It Means

Compressor motor temperature exceeded safe operating limit.

Possible Causes

  • Inadequate refrigerant charge or system overload.
  • Restricted indoor or outdoor airflow.
  • Defective compressor motor temperature sensor.

Not sure which one it is — or if it's none of these? Try ACLogics today.

Disclaimer: This information is for general reference. Error codes can vary by model and production year. Always refer to your machine's specific manual and the information printed on the unit itself.
New to this code? Click to see why this happens

Full Diagnosis

Compressor Motor Temp Out of Range Event. Compressor motor temperature is out of range.

All Recorded Causes

Check refrigerant charge and system pressures. Inspect for restricted airflow. Verify compressor motor temperature sensor. Allow compressor to cool. Inspect for overloading conditions. Board retries after 5 minutes.

Verify Before Replacing Parts

  1. Confirm the exact Bryant model family and heat pumps context before acting on a generic code description.
  2. Verify airflow first, then confirm operating pressures and temperature relationship before adjusting charge, since check refrigerant charge and system pressures.
  3. Look for restrictions, iced coils, or dirty heat-transfer surfaces that can mimic a charge problem, and separately confirm inspect for restricted airflow.
  4. After the correction, run the system long enough to confirm the heat pumps fault does not return under normal load.