Bryant Air Conditioner Error Code 55

Troubleshooting guide for the Bryant Air Conditioner system fault 55.

What It Means

Outdoor coil temperature sensor reading is out of range or disconnected.

Possible Causes

  • Faulty outdoor coil thermistor.
  • Loose or damaged sensor wiring harness.
  • Sensor unseated from coil clip.

Not sure which one it is — or if it's none of these? Try ACLogics today.

Disclaimer: This information is for general reference. Error codes can vary by model and production year. Always refer to your machine's specific manual and the information printed on the unit itself.
New to this code? Click to see why this happens

Full Diagnosis

Coil Temp Sensor Fault. Outdoor coil temperature sensor fault detected.

All Recorded Causes

Ohm out the outdoor coil temperature sensor and compare to temperature/resistance chart. Check sensor wiring and connector. Verify sensor is properly seated on the coil. Replace sensor if out of specification.

Verify Before Replacing Parts

  1. Confirm the exact Bryant model family and air conditioners context before acting on a generic code description.
  2. Confirm filter condition, blower operation, and coil cleanliness before replacing any controls — start by ruling out whether ohm out the outdoor coil temperature sensor and compare to temperature/resistance chart.
  3. Measure airflow-related readings that match the symptom, such as temperature split or static pressure, and check whether check sensor wiring and connector.
  4. After the correction, run the system long enough to confirm the air conditioners fault does not return under normal load.

Still unsure about this fault?

ACLogics walks you through Bryant Air Conditioner diagnostics step-by-step — so you confirm the cause before swapping parts.

See how ACLogics handles Air Conditioner faults →