Bryant Air Conditioner

Bryant Air Conditioner Error Code 31

Troubleshooting guide for the Bryant Air Conditioner system fault 31.

What It Means

High-pressure switch opened due to excessive discharge pressure.

Possible Causes

  • Refrigerant overcharge.
  • Dirty or obstructed condenser coil.
  • Outdoor fan motor failure or restricted airflow.

Not sure which one it is — or if it's none of these? Try ACLogics today.

Disclaimer: This information is for general reference. Error codes can vary by model and production year. Always refer to your machine's specific manual and the information printed on the unit itself.
New to this code? Click to see why this happens

Full Diagnosis

High Pressure Switch Open. High-pressure switch is open; board indicates the event and retries after 15 minutes.

All Recorded Causes

Check refrigerant charge level. Inspect outdoor fan operation and coil for airflow restrictions or debris. Verify refrigerant charge is within specification. Clean condenser coil if dirty. Board retries after 15 minutes.

Verify Before Replacing Parts

  1. Confirm the exact Bryant model family and air conditioners context before acting on a generic code description.
  2. Verify airflow first, then confirm operating pressures and temperature relationship before adjusting charge, since check refrigerant charge level.
  3. Look for restrictions, iced coils, or dirty heat-transfer surfaces that can mimic a charge problem, and separately confirm inspect outdoor fan operation and coil for airflow restrictions or debris.
  4. After the correction, run the system long enough to confirm the air conditioners fault does not return under normal load.

Still unsure about this fault?

ACLogics walks you through Bryant Air Conditioner diagnostics step-by-step — so you confirm the cause before swapping parts.

See how ACLogics handles Air Conditioner faults →