What It Means
E8 is an overcurrent trip on the inverter compressor, detected when the outdoor PCB or inverter measures current draw beyond safe operating limits during startup or run.
Troubleshooting guide for the Daikin Split & Multi-Split system fault E8.
E8 is an overcurrent trip on the inverter compressor, detected when the outdoor PCB or inverter measures current draw beyond safe operating limits during startup or run.
Not sure which one it is — or if it's none of these? Try ACLogics today.
E8 is an overcurrent trip on the inverter compressor, detected when the outdoor PCB or inverter measures current draw beyond safe operating limits during startup or run. The entire outdoor unit shuts down, and on a multi-split system every indoor unit tied to that outdoor unit loses cooling/heating since they share the single compressor. E8 differs from E5 (motor lock/overheat) and E6 (standard, non-inverter compressor overcurrent) in that it specifically targets inverter-driven compressor circuits and often points to the inverter's power stage rather than the compressor windings alone.
Compressor winding short or ground fault. Inverter main circuit capacitor degraded or failed. Power transistor (IGBT/IPM) on the outdoor unit PCB damaged. Compressor mechanically locked or seized. Refrigerant overcharge or restriction causing abnormal discharge pressure and current draw. Loose or corroded compressor terminal (UVW) connections.