What It Means
U5 covers a transmission failure between the indoor unit and its wired remote controller, meaning the fault is isolated to the control-signal link rather than the refrigerant or power circuits.
Troubleshooting guide for the Daikin Split & Multi-Split system fault U5.
U5 covers a transmission failure between the indoor unit and its wired remote controller, meaning the fault is isolated to the control-signal link rather than the refrigerant or power circuits.
Not sure which one it is — or if it's none of these? Try ACLogics today.
U5 covers a transmission failure between the indoor unit and its wired remote controller, meaning the fault is isolated to the control-signal link rather than the refrigerant or power circuits. Only the indoor unit tied to that remote controller is affected; other indoor units on a multi-split keep running normally. U5 is distinct from U4 (indoor-to-outdoor communication) and U7 (outdoor-to-outdoor communication) — it is the only one of the three transmission codes confined entirely to the indoor-unit-to-controller leg of the system.
Damaged, disconnected, or miswired cable between the indoor unit and remote controller. Two main (master) remote controllers connected simultaneously without one set to sub/slave. Loose or corroded connector at either end of the remote controller wiring. Electrical noise or interference near the low-voltage control wiring. Defective indoor unit PCB transmission circuit. Defective remote controller PCB.