What It Means
J6 covers a failed outdoor unit heat exchanger thermistor — the sensor that tracks the outdoor coil's refrigerant temperature for defrost timing and capacity control — reading open, shorted, or implausible.
Troubleshooting guide for the Daikin Split & Multi-Split system fault J6.
J6 covers a failed outdoor unit heat exchanger thermistor — the sensor that tracks the outdoor coil's refrigerant temperature for defrost timing and capacity control — reading open, shorted, or implausible.
Not sure which one it is — or if it's none of these? Try ACLogics today.
J6 covers a failed outdoor unit heat exchanger thermistor — the sensor that tracks the outdoor coil's refrigerant temperature for defrost timing and capacity control — reading open, shorted, or implausible. Because this thermistor feeds outdoor-side control logic, the fault takes down the whole outdoor unit and, on a multi-split, every connected indoor unit. J6 is distinct from its neighbors J8 and J9, which monitor the liquid and gas refrigerant piping thermistors respectively rather than the coil body itself, and from J3, which covers the compressor discharge pipe thermistor.
Heat exchanger thermistor open or shorted internally. Thermistor bulb detached from the coil surface, losing accurate contact. Connector corroded, loose, or disconnected at the outdoor PCB. Wiring harness damaged by vibration, rodents, or sharp edges. Defective outdoor unit PCB thermistor input.
ACLogics walks you through Daikin Split & Multi-Split diagnostics step-by-step — so you confirm the cause before swapping parts.