What It Means
PA indicates a broken or open heater element circuit within the humidifier unit accessory occasionally paired with Daikin split systems, detected as a wiring or continuity failure rather than a temperature-related fault.
Troubleshooting guide for the Daikin Split & Multi-Split system fault PA.
PA indicates a broken or open heater element circuit within the humidifier unit accessory occasionally paired with Daikin split systems, detected as a wiring or continuity failure rather than a temperature-related fault.
Not sure which one it is — or if it's none of these? Try ACLogics today.
PA indicates a broken or open heater element circuit within the humidifier unit accessory occasionally paired with Daikin split systems, detected as a wiring or continuity failure rather than a temperature-related fault. This shuts down humidifier operation and, depending on the model's control logic, can also halt the associated indoor unit until the fault is cleared. PA differs from P9 (which is a humidifier fan motor failure) and PH (which relates to the refrigerant charging cylinder heater during factory/service charging) — PA is specifically the broken-wire condition on the humidifier's own heating element.
Heater element wire broken or burned open. Heater unit failed internally (element burnout). Loose or corroded connector between the heater and outdoor/indoor PCB. Damaged heater harness from moisture intrusion or vibration chafe. Thermistor monitoring the heater circuit reading out of range and triggering a false trip.
ACLogics walks you through Daikin Split & Multi-Split diagnostics step-by-step — so you confirm the cause before swapping parts.